서지보호기-SH-B60_4P
SH-B60
APPLICATIONS Protect your measuring environment from surges or surges status indication Green: Normal / Red: Connection Failed PROTECTION FUNCTION Thermal & Short Circuit Fuse, 2-Stage Surge Protect Noise Filtering (EMI/RFI)
Protection class IP20 additional accessories External circuit breaker SHSCB series applicable  MOUNTING  DIN RAIL
Applicable standard IEC 61643-11

Mode SH-B60 Maximum operating voltage (Uc) 275V/AC OR 385V/AC
IEC TYPE 2, T2 Response time N-PE 25nsec
surge protection device Voltage limiting type, combination type Backup Protection Options for Breakers SHSCB-60
mode 1P ,2P ,3P ,4P / 1+NPE , 3+NPE Connection cable cross-section  4-35mm
Nominal voltage (Uo) 220V AC/ 220V AC/ 380V AC/ 380V AC mounting method  35mm DIN Rail
Nominal discharge current (In) 8*20μsec LN 30 kA operating temperature -40~70℃
Maximum discharge current (Imax) 8*20μsec LN 60 kA ip code IP20/NEMA12
Voltage protection level (Up) 8*20μsec LN 2.2kV case material plastic
Short circuit rated current (Iscpv0 25 kA Mounting DIN RAIL