Digital transmitter
UHLIS 0040
    4개의 격리된 디지털 입력(Dry contacts) 또는 임펄스(NPN, PNP)로 UHLIS 0040T0을 통해 4개 모두를 유연하게 구성할 수 있습니다

    모드버스 RTU 연결을 통한 상태 전송 또는 임펄스 카운팅을 위한 입력. UHLIS 0040T0는 5년이 보장됩니다

Technical Data
Products Detail

Presentation
4개의 격리된 디지털 입력(Dry contacts) 또는 임펄스(NPN, PNP)로 UHLIS 0040T0을 통해 4개 모두를 유연하게 구성할 수 있습니다
모드버스 RTU 연결을 통한 상태 전송 또는 임펄스 카운팅을 위한 입력. UHLIS 0040T0는 5년이 보장됩니다

 

 

 

 

Inputs

Functioning mode

Counting direction

Scale factor value

Counter reset value

Counting

Increasing

1.0

0.0

Alarms thresold mode

Alarm 1 thresold

Alarm 1 thresold

 

Unused

0.0

0.0

 

 

Functions

Function performed

Operand A

Operand B

Operand C

Unused

Input 1

Input 1

Input 1

 

  • Inputs – Communication

 

  • Input gauges

 

 

Input

4 digital inputs: NPN, PNP, dry contacts Acceptable voltage range 0-24V

Vil: 2V ; Vih: 10V

Sensor supply

2 wires sensor 24V ; 41mA max

Communication

Isolated USB front panel / Isolated RS485 Modbus RTU

 

  • Characteristics

 

Input characteristics

 

 

Current input impedance

> 4.7 kΩ Active state

>11 MΩ Passive state

Isolation

 

Supply / Inputs-Communication

4200Vrms, 50Hz,1mn

Input x / Input y / USB-RS485

2500Vrms, 50Hz,1mn

USB / RS485

Without

Auxiliary source

 

Voltage supply

22-240Vdc or 90-230Vac 50/60Hz

General characteristics

 

 

Max frequency of counting / of a digital signal

Counting max frequency:

1 channel: 2.4 kHz ; 2 channels: 2.2 kHz ; 3 channels: 2 kHz ; 4 channels:

1.8 kHz

Maximum of consumption

<5 VA

Operating temperature

-10°C … +60°C

Storage temperature

-25°C … +80°C

Relative humidity

<95% HR (non-condensing)

Protection factor

IP20

 

  • Functions

 

Technical Data

Display functions

 

 

LED indicators

4 red LEDs light up or down depending on the state of the input

1 LED indicates that a communication is in progress (USB or RS485)

Programming

Programming via USB with IXLOG software

Smart functions

 

Calculation mode

Functions configurable: A+B, A+B+C, A+B+C+D, A-B, A/B, (A-B)/A

Memorization of Digital input states

Copy status of digital inputs to bits for transmission via Modbus

 

 

Counter input

Counting direction: increase, decrease

Possibility to enter a multiplier factor on the value of each input

Possibility to define 2 alarm thresholds per channel

Possibility to reload the counter with an initialization value set when the second threshold is exceeded

Reloading a counter with an initialization value by setting a bit

Links and communication

 

 

RS485 MODBUS RTU

RS485 MODBUS RTU bidirectional digital link allowing to:

recover the measurements and transmit them in digital format

configure and control the device

USB front

USB front panel to connect directly to the USB port of a PC for programming via the IXLOG software

 

Model
Function
Input
Output
Power
Accuracy
Display
Response Time
Front Adjustment
Weight
Mounting
Dimensions(mm)